Effect of Heat Treatment and SrO Co-doping on the Thermoluminescence of Dy2O3-Doped MgSO4 Powder Irradiated with 241Am Gamma Rays

Authors

  • Izleen Laili Ibrahim School of Physics, Universiti Sains Malaysia, 11800 USM, Penang, Malaysia Author
  • Iskandar Shahrim Mustafa School of Physics, Universiti Sains Malaysia, 11800 Minden, Pulau Pinang, Malaysia Author
  • Muhammad Fadhirul Izwan Abdul Malik Science and Engineering Research Center, USM Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Malaysia Author
  • Hayder Salah Naeem Science Department, College of Basic Education, Al-Muthanna University, 66001 Samawah, Al Muthanna, Iraq Author
  • G.I. Efenji Federal University Lokoja, P.M.B. 1154, Lokoja, Kogi State, Nigeria Author

DOI:

https://doi.org/10.66514/ssst34-2-186-198

Keywords:

Thermoluminescence, Magnesium sulphate, Dysprosium, Strontium oxide, Powder dosimeter

Abstract

Magnesium sulphate is an inexpensive host for thermoluminescence (TL) dosimetry, but its intrinsic sensitivity is low. Dy doping is known to sensitize MgSO4, but the effects of SrO co-doping and of the heat-treatment temperature on Dy2O3-doped MgSO4 powder have not been reported, and its response to low-energy photons at the microgray doses relevant to occupational monitoring has received little attention. In this work, MgSO4 powders containing Dy2O3 (about 3.9 mol%) and SrO (x = 0, 0.03 and 0.05, corresponding to 0, 2.5 and 4.2 mol% in the batch) were prepared by solid-state mixing and heat treatment at 400, 800 and 900 °C for 6 h. FESEM showed micrometer-sized angular particles after treatment at 400 °C and partially sintered, agglomerated particles at 800–900 °C. EDX confirmed the presence of Mg, S, O, Dy and Sr, but the Dy content varied widely between samples, indicating incomplete homogenization. Aliquots were irradiated with 59.5 keV gamma rays from a 3.5 GBq 241Am source for 15–60 min (nominal doses 50–200 µGy) and read with a Harshaw 3500 reader at 10 °C s−1 to 300 °C. The powders treated at 400 °C showed no glow peak, and their integrated signal (3–6 nC) was at the reader background level. Treatment at 800 and 900 °C produced a strong glow peak that was still rising when the readout reached 300 °C, together with a weaker shoulder at about 175–250 °C. At 800 °C, SrO co-doping increased the mean integrated TL about three-fold (from 19 to 58–64 nC), and raising the treatment temperature from 800 to 900 °C increased it a further 9–19-fold. Within 50–200 µGy, the integrated TL did not increase systematically with dose (R2 ≤ 0.68, aliquot-to-aliquot variation 5–78%); only the 800 °C, x = 0.03 powder showed a positive trend (0.20 nC µGy−1, R2 = 0.36). Heat treatment at 800–900 °C and SrO co-doping clearly sensitize MgSO4:Dy, but a higher readout temperature, mass-normalized replicate aliquots and calibrated irradiations are needed to establish its dose response.

References

[1] International Commission on Radiological Protection. The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP. 2007;37(2–4):1–332. https://doi.org/10.1016/j.icrp.2007.10.003

[2] Izewska J, Rajan G. Radiation dosimeters. In: Podgorsak EB, (ed.) Radiation Oncology Physics: A Handbook for Teachers and Students. Vienna: International Atomic Energy Agency; 2005. p. 71–99. https://www.iaea.org/node/40955

[3] McKeever SWS. Thermoluminescence of Solids. Cambridge: Cambridge University Press; 1985. https://doi.org/10.1017/CBO9780511564994

[4] Bos AJJ. Theory of thermoluminescence. Radiation Measurements. 2006;41(Suppl. 1):S45–56. https://doi.org/10.1016/j.radmeas.2007.01.003

[5] Lawless JL, Chen R, Pagonis V. Sublinear dose dependence of thermoluminescence and optically stimulated luminescence prior to the approach to saturation level. Radiation Measurements. 2009;44(5–6):606–10. https://doi.org/10.1016/j.radmeas.2009.03.003

[6] Rapley P. Surface dose measurement using TLD powder extrapolation. Medical Dosimetry. 2006;31(3):209–15. https://doi.org/10.1016/j.meddos.2006.02.003

[7] Rah JE, Hong JY, Kim GY, Kim YL, Shin DO, Suh TS. A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter. Radiation Measurements. 2009;44(1):18–22. https://doi.org/10.1016/j.radmeas.2008.10.010

[8] Luo DL, Yu KN, Zhang CX, Li GZ. Thermoluminescence characteristics and dose responses in MgSO4:Dy,P and MgSO4:Dy,P,Cu phosphors. Journal of Physics D: Applied Physics. 1999;32(23):3068–74. https://doi.org/10.1088/0022-3727/32/23/313

[9] Zahedifar M, Almasifard F, Sadeghi E, Kashefi Biroon M, Ramazani-Moghaddam-Arani A. Thermoluminescence kinetic analysis and dosimetry features of MgSO4:Dy and MgSO4:Cu nano-rods. Radiation Physics and Chemistry. 2016;125:127–33. https://doi.org/10.1016/j.radphyschem.2016.04.005

[10] Zahedifar M, Almasifard F, Sadeghi E, Harooni S, Kashefi Biroon M. Thermoluminescence dosimetry properties and kinetic analysis of MgSO4:Dy microcrystalline prepared by solid state method. Radiation Measurements. 2017;103:26–32. https://doi.org/10.1016/j.radmeas.2017.06.006

[11] Gasiorowski A, Szajerski P. Particles size increase assisted enhancement of thermoluminescence emission in gadolinium and dysprosium oxide doped phosphate glasses. Journal of Alloys and Compounds. 2020;839:155479. https://doi.org/10.1016/j.jallcom.2020.155479

[12] Gavhane KH, Bhadane MS, Kulkarni PP, Bhoraskar VN, Dhole SD, Dahiwale SS. Investigation of novel Eu doped SrDy2O4 microphosphor for thermoluminescence dosimetry. Journal of Luminescence. 2021;231:117781. https://doi.org/10.1016/j.jlumin.2020.117781

[13] Sarikci S, Topaksu M, Madkhali O, Can N. Thermoluminescence characteristics and kinetic analyses of europium doped strontium gadolinium oxide phosphor. Applied Radiation Isotopes. 2023;191:110549. https://doi.org/10.1016/j.apradiso.2022.110549

[14] Saharin NS, Ahmad NE, Tajuddin HA, Tamuri AR. Thermoluminescence properties of aluminium oxide doped strontium, lithium and germanium prepared by combustion synthesis method. EPJ Web Conference 2017;156:00001. https://doi.org/10.1051/epjconf/201715600001

[15] Salleh NA, Tamuri AR, Saeed MA. Effect of strontium concentration on thermoluminescence glow curve of copper doped lithium magnesium borate glass. Malaysian Journal of Fundamental Applied Sciences 2017;13(3):275–8. https://doi.org/10.11113/mjfas.v13n3.570

[16] Rezaee Ebrahim Saraee K, Lotfi M. Gamma ray dosimetric properties of Tb- and Dy-doped Ba0.88Sr0.12SO4 phosphor. Iranian Journal of Science and Technology Transactions A: Science. 2020;44:1549–58. https://doi.org/10.1007/s40995-020-00945-w

[17] Mohamed S, Salama E, Alazab HA, Bakry A, Sharma A, Assran Y. Synthesis and characterization of high-sensitivity Dy,Eu co-doped CaSO4 thermoluminescent phosphor using coprecipitation technique. Luminescence. 2024;39(1):e4679. https://doi.org/10.1002/bio.4679

[18] Guckan V, Bereket S, Altunal V, Abusaid W, Yegingil Z. Luminescence properties of Tb and Eu activated CaSO4 phosphor. Radiation Physics and Chemistry. 2023;203:110620. https://doi.org/10.1016/j.radphyschem.2022.110620

[19] Silva AMB, Rodrigues DS, Guedes BDO, Silveira IS, Antonio PL, Junot DO, et al. Exploring the luminescence properties and dosimetric characteristics of CaSO4:Tb, CaSO4:Mn, and CaSO4:Mn,Tb phosphors synthesized by slow evaporation route. Radiation Measurements. 2024;177:107261. https://doi.org/10.1016/j.radmeas.2024.107261

[20] Silva AMB, Junot DO, Antonio PL, Souza DN, Caldas LVE. Analysis of dosimetric characteristics of CaSO4:Mn,Tb phosphors synthesized by four different routes. Applied Radiation Isotopes. 2026;229:112381. https://doi.org/10.1016/j.apradiso.2025.112381

[21] Almasifard F, Zahedifar M. Thermoluminescence dosimetry characteristics of MgSO4:Eu microcrystalline in gamma radiation. Radiation Physics and Chemistry. 2025;232: 112606. https://doi.org/10.1016/j.radphyschem.2025.112606

[22] Naeem HS, Mustafa IS, Yusof NN, Thabit HA, Mhareb MHA, Alajerami YSM, et al. High sensitivity transparent glass ceramic systems development based on MgSO4:Dy2O3–B2O3 and MgSO4:Dy2O3–B2O3:ZnO: an investigation of FT-IR and thermal properties for thermoluminescence dosimeter applications. Optical Materials. 2024;156:116003. https://doi.org/10.1016/j.optmat.2024.116003

[23] Naeem HS, Mustafa IS, Yusof NN, Raypah ME, Thabit HA, Mhareb MHA, et al. Altering the optical, physical, and TL dosimetric properties of MgSO4:Dy2O3:B2O3 transparent glass ceramic system: evaluating the impact of roughness control and ZnO inclusion. Journal of Non-Crystalline Solids. X. 2024;22:100212. https://doi.org/10.1016/j.nocx.2024.100212

[24] Shannon RD. Revised effective ionic radii and systematic studies of interatomic distances in halides and chalcogenides. Acta Crystallographica A. 1976;32(5):751–67. https://doi.org/10.1107/S0567739476001551

[25] Saraswathi AV, Naregundi K, Sayyed MI, Almousa N, Kamath SD. Influence of annealing temperature on the structural and luminescence features and thermoluminescence trap parameters of Ca2Al2SiO7:Ce3+ phosphors. JOM. 2024;76(1):566–77. https://doi.org/10.1007/s11837-023-06184-9

[26] Girão AV, Caputo G, Ferro MC. Application of scanning electron microscopy–energy dispersive X-ray spectroscopy (SEM-EDS). Comprehensive Analytical Chemistry. 2017;75:153–68. https://doi.org/10.1016/bs.coac.2016.10.002

[27] Bakhsh M, Yasuda H, Ahmad N, Wong JHD, Mustafa IS. Zinc-doped magnesium borate glass: a potential thermoluminescence dosimeter for extended range of dosimetric applications. Applied Sciences. 2022;12(15):7491. https://doi.org/10.3390/app12157491

[28] Terada K, Nakamura S, Nakao T, Kimura A, Iwamoto O, Harada H, et al. Measurements of gamma-ray emission probabilities of 241,243Am and 239Np. Journal of Nuclear Science and Technology. 2016;53(11):1881–8. https://doi.org/10.1080/00223131.2016.1174167

Downloads

Published

19-11-2026

Similar Articles

111-120 of 187

You may also start an advanced similarity search for this article.