MICRODROPLET ELECTROWETTING ACTUATION ON FLEXIBLE PAPER-BASED PLATFORM CHIP
Keywords:
Microdroplet, Electrowetting, Flexible device, Aluminium electrode, Paper based chipAbstract
This paper presents the microdroplets electrowetting causing by the voltage actuation on the flexible platform chip. A 5µl of Potassium Chloride (KCl) microdroplet is pipetted on top of two separated electrodes fabricated on this flexible platform chip. The electrode is made of a thin Aluminium (Al) film while the platform substrate is made from the cellulose paper, which is flexible. The voltage is supplied between the two separated planar electrodes to actuate the microdroplet motion. In this experiment, the best point of low voltage to move the microdroplet between the two planar electrodes is 12Vpp where the microdroplet is observed to move far and give higher displacement from its origin under the frequency of 10Hz.
Downloads
Published
Issue
Section
License
Copyright (c) 2018 Nurul Amziah Md Yunus, Noor Faezah Ismail, Nasri Sulaiman, Mohd Nazim Mohtar, Desa Ahmad (Author)